ITC – VA-6100P85 8-zone Amplifier
& Free Shipping
| Brand Name: | ITC |
| Part Number: | VA-6100P85 |
| Product Type: | ITC – VA-6100P85 8-zone Amplifier |
| Specification: | Please refer to the Datasheet on the Manufacturer’s Datasheet |
| Warranty: | Manufacturer Standard Warranty |
- Applicable on : Orders above Rs. 500.
- Bank offer : 5% Cashback on paypal card.
- Coupon code : Use code "FLIPMART10OFF".
- Delivered : Usually delivered in 6 days.
ITC – VA-6100P85 8-zone Amplifier
DETAILS:
ITC – VA-6100P85 8-zone Amplifier
Descriptions:
2U cabinet design is built-in a 500W digital amplifier and integrated to be 8 zones, can be installed in the broadcasting room or remote control room, share the network audio source with the system via Ethernet, and support 4 channel local signal inputs. It’s the ideal choice for small or medium system.
Features:
- Support the speaker loop grounding, open circuit and short circuit detection.
- Support the speaker loop 3 /4 wired cabling
- 8 Programmable trigger input interfaces.
- 8 Programmable trigger output interfaces.
- Support power amplifier enter power saving mode to save energy when no signal input.
- Support linkage with fire alarm control unit to realize fire alarm linkage control.
Specifications:
| AC power | |
| Voltage | AC 220V±20% 50-60Hz |
| Maximum current | 3A |
| Fuse | 250V/3.15A,slow type |
| DC power | |
| Voltage | DC24VC, 18-31V adaptive |
| Maximum current | 30A |
| Maximum Power consumption | 600W |
| Performance Index | |
| Number of output partitions | 8 |
| Output voltage | 100V optional |
| Output type | Bridge-tied output without transformer boost |
| Output power | 500W (maximum output of a single partition) |
| Distortion | <1% (rated output power), 1KHz |
| Frequency response | 80Hz-16KHz |
| SNR | >70dB |
| Maximum output power | 500W |
| Override type | 3-wire and 4-wire |
| 4-wire override output voltage | 24V |
| Power amplifier status detection time | < 0.5S |
| Partition detection status | Short circuit, open circuit, short circuit to ground |
| Partition detection time | < 0.5S |
| Contact Output | |
| 8 channels programmable relay output | Short Circuit, No voltage |
| 8 channels programmable trigger input | Short-circuit input, short-circuit input with detection, voltage input |
| Short circuit mode | 3.3V voltage, short-contact trigger, no linkage line monitoring function |
| Short circuit mode with detection | 3.3V voltage, short-contact trigger, support linkage line fault alarm |
| Voltage mode | 18-31V voltage input, voltage trigger, support linkage line fault alarm |
| Cooling mode | Air-Cooled |
| Protection mode | Delay/Overheat/Short Circuit/Over Load |