APC – MGE GALAXY 300, 30, KVA 400V
& Free Shipping
MGE GALAXY 300 30 KVA 400V
- Applicable on : Orders above Rs. 500.
- Bank offer : 5% Cashback on paypal card.
- Coupon code : Use code "FLIPMART10OFF".
- Delivered : Usually delivered in 6 days.
APC? – MGE GALAXY 300 30 KVA 400V
Brand Name: APC
Part Number: G3HT30KHB2S
Product Type: APC? MGE GALAXY 300 30 KVA 400V
Specification: Please Refer Datasheet on Manufacturer Website
Warranty: Manufacturer Standard Warranty
Details:
Effective three phase power protection against downtime and data loss for mission critical
applications. Ruggedized version including dust filter and conformance coated boards for harsh
environments.
Output:
Output Power Capacity – 24.0 KW / 30.0 kVA
Max Configurable Power (Watts) – 24.0 KW / 30.0 kVA
Nominal Output Voltage – 400 3PH
Output Voltage Note Configurable for – 380: 400 or 415 V 3
Phase nominal output voltage
Output Voltage Distortion – Less than 5%
Output Frequency (sync to mains) – 50/60 Hz +/- 5%
Other Output Voltages – 380, 415V
Crest Factor – 2.5: 1
Crest Factor – Double Conversion Online
Waveform Type – Sine wave
Output Connections – (1) Hard Wire 5-wire (3PH + N + G)
(Battery Backup) 2
Output Voltage Tolerance –? ?+/- 2%
static and 100% load step
Output Voltage THD – ??
Overload Operation – 60 seconds @ 120% and 30 seconds @ 145%
Required Output Current Protection – 125 A
Input:
Nominal Input Voltage – 400 3PH
Input Frequency – 45 – 65 Hz
Input Connections – Hard Wire 5-wire (3PH + N + G)
Input voltage range for main operations – 340 – 477 V
Input voltage adjustable range for mains operation – 323 –
437 (380V) V, 340 – 460 (400V) V, 357 – 477 (415V) V
Other Input Voltages – 380, 415
Maximum Input Current – 47 A
Input Breaker Capacity – 125 A
Input Total Harmonic Distortion – Less than 5% for full load
Type of Input Protection Required – GL fuse
Batteries & Runtime
Battery Type – Maintenance-free sealed Lead-Acid battery
with suspended electrolyte: leakproof
Included Battery Modules – 0
Battery Slots Empty – 0
Typical recharge time – 0 hour(s)
RBC Quantity – 0
Nominal Battery Voltage –? ?+/-192
V (split battery referenced to neutral)
End of Discharge Battery Voltage – ??+/-154V
Overload Operation – 60 seconds @ 120% and 30 seconds @ 145%
Communications & Management:
Available SmartSlot? Interface Quantity – 0
Pre-Installed SmartSlot? Cards – AP9630
Control panel – Multi-function LCD status and control
console
Emergency Power Off (EPO) – Yes
General Inquiries
There are no inquiries yet.
Reviews